Fm 200 fire suppression system design pdf

Troublefree design for safe and easy application compact, aesthetic and easy to move available in 2 cabinet sizes userfriendly standardized owners manual with every unit. Fm200 fm200 is a registered trade mark of the du pont system in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release engineered hydraulic flow program used to predict the two phase flow of fm200 through a pipe network contacts. Once the fm 200 fire suppression system discovers a fire in the room, the fm 200 system can respond in a matter of seconds, flooding the area with the extinguishing agent and preventing the fire from. Our fm200 system offers three different nozzle types in seven different sizes, with expansive vertical and horizontal coverage from each single nozzle. Fm 200 is a fast reacting, effective, clean agent system that can reduce the damage of a fire as it leaves behind no residue. Fm200 will extinguish a fire utilizing a combination of chemically based products that inhibited the fire. Fm 200 total flooding fire suppression system data specification sheet general the fm 200 fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. Fm200 fire suppression systems, safety, applications. Common fire suppression clean agents inert, novec 1230, and.

Fm200 clean agent fire suppression system hfc227 fike. Fm listed approved pn 45n1230m001 february 2005 ul listing file no. Constant flow the installer must ensure the correct pressure rating for pipes and fittings acc. These systems offer the most versatile clean agent suppression systems available for any business, big or small. Fm200 extinguishing system units are to be designed, installed, inspected. Nfpa 2001 standard on clean agent fire extinguishing systems, nfpa 70 national electrical code. Fm200 fire suppression system multron systems pte ltd. Fm200 clean agent fire suppression system fast, effective clean agent fire protection. A world of protection 4801 southwick drive, 3rd floor matteson, il 60443. This article provides a comparison of these three popular clean agents to help you decide which might be best for your needs. Fm200 does not displace oxygen and therefore is safe for use in occupied spaces without fear of oxygen deprivation. Fm 200 clean agent fire suppression system fast, effective clean agent fire protection. This specification outlines the requirements for a crosszoned detection and total flooding fm 200 fire suppression system. Fm200 fire suppression system costeffective protection for.

Marine system with uscg and abs approvals also available. Ssi offers hfc227eafm200 clean agent fire suppression systems through our quality line of fike products. International journal on engineering performancebased fire codes. Fm200 is a chemical agent used primarily in total flooding systems and has been installed in over 200,000 systems worldwide. The fm 200 system is ideal for areas occupied by personnel and containing assets that could be damaged by water. Fm200 is a waterless fire protection system, it is discharged into the risk within 10 seconds and suppresses the fire immediately. Factory mutual fm fm 200 systems are manufactured in strict accordance with the internationally recognised quality assurance standard, bs en is0 9000 and approved to iso 9001. Costeffective protection for highvalue assets highvalue assets such as data and sensitive equipment demand the quality fire suppression offered by the ansul fm200 fire suppression system. Fm 200 fire suppression system fire extinguisher in singapore. Fm 200 extinguishing system units are to be designed, installed, inspected, maintained, tested and recharged by qualified, trained personnel in accordance with the.

The three most common clean agents on the market today are inert gas inergen, nitrogen, argonite, novec 1230, and fm 200, which has been a mainstay of fire suppression systems for more than 20 years. Download fm 200 firefighting project autocad drawings for free. Fm200 suppression systems majestic fire protection. Located in over 80 countries worldwide, our highly skilled authorized distributor network designs. Fm 200 fire suppression system is often used to extinguish electrical control panels and electrical distribution rooms, where the fire place is tightly sealed because the fm 200 extinguisher replaces oxygen. Fm200 navec1230 co 2 inergen ig55 20 40 80 100 120 25 60 constant flow 200300 bar pipe pressure downstream the pressure reducing unit. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems.

Statx fire suppression system animation video duration. The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing. Fm200 fire suppression is also a widely accepted replacement for halon 1. It doesnt leave any residue after release or cause damage to it equipment and documents. Integrated fire protection system 1230 fire suppression systems.

Fm200 suppression systems fm200 is one of the best halon replacement systems on the market. The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. Fm 200 fire suppression system is a waterless fire protection system designed to be discharged within 10 seconds into the area and extinguish the fire immediately. Nov 05, 2009 fm 200 fire suppression systems go to. A fixed fire suppression system is more difficult to design than in an engine test cell, both because of the larger volume of vehicle test cells and because access to the seat of the fire is difficult since it may well be within the vehicles engine bay. Fm200 is a colourless gas which is liquified under pressure for storage. The department expects a turnkey solution for this project. Activated by smoke or heat, robovents supprex 200 acts quickly to suppress a fire. Data center fire suppression systems fm 200 system design. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection.

Since 1917, kidde fire systems has been a global leader in fire protection, protecting people, property, and processes from fire hazards. After receiving the fire signal, fm 200 is discharged totally from the cylinders within 10 seconds to fill up the space uniformly at the design concentration to extinguish the fire. Airflow is shut off, and, if needed, fm 200 gas is deployed. When you consider the potentially devastating environmental effects of an uncontrolled fire, its easy to see that an fm200 system is an important. Fm200 total flood fire suppression systems design, installation, and maintenance manual one. Amongst all gaseous suppression systems, fm 200 system design is most commonly use. Fm200 fire suppression is a suitable agent for normally occupied spaces. Fm 200 1,1,1,2,3,3,3heptafluoropropane, cf3chfcf3 is a colorless odorless gas, low in toxicity, electrically nonconductive, leaves no residue, and is an extremely effective fire suppression agent. Our systems are based on many years experience in the design, supply. Fm200 total flooding fire suppression system general the fm200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. Partnering with the experts in the field, 3s can design and install fm 200 fire suppression systems for your industrial application.

The system is designed and installed in accordance with the national fire protection association nfpa standard 2001, clean agent fire extinguishing systems. Costeffective protection for highvalue assets highvalue assets such as data and sensitive equipment demand the quality fire suppression offered by the hygood fm 200 fire suppression system. This clean agent is very safe for occupied spaces and nontoxic when used in accordance with nfpa standard 2001. The final peak pressure in the pipe will result from the hydraulic flow calculation. Fm200 fire suppression systems protect everything from computer rooms data centres, telecommunications facilities, and switch gear to military vehicles, high tech medical applications, and pleasure craft to. Fm200 fire suppression systems are commonly used in. Pdf fm200 ecs series engineered fire suppression systems. Fm 200 is included in nfpa2001, under the generic name hfc227ea, and has been evaluated and. Fm200 data and specification sheet pc2008 pyrochem. Fire suppression using the fm 200 system has the following advantages. Extensively tested, fm200 systems are proven safe for use in occupied areas. Kidde fenwal fm 200 fire suppression systems are environmentallyfriendly and a halon 1 alternative. The to contractor is to provide all labor, tools, equipment, hardware and consumables to furnish and to install a fully integrated and functional fm200 fire suppression system.

The fm 200 fire suppression system contains sensitive detectors that can detect even the smallest fires. Ex 4674 fm approvals project id 3020593 kidde engineered fire suppression system designed for use with 3m novec 1230 fire protection fluid design, installation, operation and maintenance manual. The fire fighting ability of the fm 200 system is achieved through 80% heat absorption and 20% direct chemical means action of the fluorine radical on the chain reaction of a flame. Janus fire systems clean agent fire extinguishing systems are engineered systems, meaning they offer maximum flexibility to tailor each system design according to the location they protect. The system owner shall maintain an instruction and maintenance manual, full set of system drawings. Within 10 seconds or less, it should be able to stop ordinary combustible, flammable liquid and electrical fire before they can cause severe damage.

Fire suppressants the fire protection modern businesses need. Agent fm200 fire suppression system to be located in the new data center on the 5th floor of the wtcb. The design extinguishing concentration ranges are from 7. Utilizing the industry recognized fm200 suppression agent, amerex has developed an. Chemours brings a history of leadership in fire protection, making it a driving force in the development of safe, clean alternatives to commonly used fire suppression systems in military applications, cultural property, data centers, and other critical installations. Aug 25, 2000 fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems.

Fm200 must be used with properly designed, installed. We specialize in the design of fm 200, co2, foam, and water based fire protection systems as well as alarm and detection. Janus fire systems is a full service fire protection company formed of professionals experienced in special hazard and industrial fire protection. Fm200 total flooding fire suppression system data specification sheet general the fm200 fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. The amount of oxygen must be constant and nonrenewable. As the extinguishing abilities of fm200 determine that only 70%. Fm 200 is not a direct replacement for existing halon 1 installations due to the difference in agent quantity and discharge characteristics the minimum fm 200 design concentration for class a hazards is 6 4% for ul listed systems or 7 17% for fm approved systems, and for class b hazard is at least 9 0%. They are designed using bespoke software, which accurately calculates the amount. The fm200 fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network.

559 676 1075 1393 792 1231 131 85 653 1265 682 394 1146 1554 1378 845 953 1555 1079 187 826 524 1357 1224 559 772 1179 605 1007